ELAD®

Dual Axis Inclinometer

The ELAD® Dual-Axis Inclinometer, is a Dual-Axis family of Inclinometers, well positioned at the hi-end dual-axis systems providing servo-level performances at a much lower price point. Unlike MEMS-based sensors, the ELAD® is based on well-proven micro-capillary capacitive technology, featuring superior long-term stability and non-Linearity to assure best performance possible at this level.

Dedicated Hi Performance Analog-to-Digital converter provides the necessary analog front-end in terms of hi-resolution, non-linearity and temperature compensated measurements. Built-In Hi Performance µController handling all compensation and
computation tasks along with the communication protocol.

Dedicated mathematical modeling and calibration procedure taking care of Temperature compensation, Scale-Factor, Cross-
Axis, to assure high-performance results at various changing environmental conditions.

Main Features

Hi Precision System, down to < 1mRad over Temp Range

Exceptional long-term stability

Wide Range of voltage supply (9-32 VDC)

Low-Power consumption

Mil-Spec Compliance

Applications

Antenna Alignment

Platform Leveling

Optical Observation Systems

Radar leveling

Pedestals alignment

Specifications

ParamaterValue (Typical)
Measuring range±10°±30°
Resolution< 0.001°< 0.003°
Accuracy< 0.02°< 0.03°RMS, at room temp
< 0.05°< 0.06°RMS, over -10°C to +60°C
Linearity deviation< 0.05 %< 0.03 %
Repeatability< 0.001°< 0.003°
Hysteresis< 0.001°
Frequency3 Hz (-3dB, Typical)
Temperature drift of sensitivity< 50 ppm / °C (typical)
Temperature drift of zero point< 1 arc-sec / °C (typical)
Supply Voltage9V - 32V DC
Current Consumption< 150 mA
Start Up Time< 500 mSec
Communication InterfaceRS232 (optional RS422)
Baud Rate4,800 - 115,200 bps
Output Rateup to 10 frames / sec
Dimensions150 x 110 x 70 mm
Weight< 1.4 Kg
Power/Data ConnectorsDeutsch DTS24W15-35PN
Temperature-40º C to +85º C Mil-Spec 810-G Method 501.5 Procedure II
Humidity95% non-condensing Mil-Spec 810-G Method 507.5 Procedure II
Shock20g, 11 msec ½ Sine Mil-Spec 810-G Method 516.6 Procedure V
Vibration6.5 grms, 5-800 Hz Mil-Spec 810-G Method 514.6 Procedure I
EnclosureIP67EN 529
RainMil-Spec 810-G Method 506.5 Procedure I
DustMil-Spec 810-G Method 510.5 Procedure I
Salt/FogMil-Spec 810-G Method 509.5
Power SupplyMIL-STD-1275B
EMI/RFIMIL-STD-461C/D
MTBF> 100,000 hours according to Mil-HDBK 217

DOCUMENTATION AND RESOURCES

Interested in ELAD®?